Interferential current stimulation is effective upon the Nerves, Muscles, Arteries, and Veins. The current is able to penetrate tissues to a much greater depth, with a soft simulative effect, thus assuring an exclusive range of application.
Product Specifications:
* Russian Current: 2500Hz Carrier frequency.
* Medium Frequency: 2 kHz and 4 kHz.
* IF Out-Put; Channel-1, 4000 - 4250Hz depending on the base & spectrum control.
: Channel-2, 4000Hz (Constant)
* Base AMF: 0 to 100 Hz.
* Sweep AMF: 0 to 150 Hz.
* Form: 3 Position, Rectangular 1/1 Sec., Trapezoidal 1/5 Sec., Triangular 6/6 Sec.
* Therapy Mode:
: A, Four Pole, 45 deg. Vector IFT.
: B, Four Pole, 90 deg. Vector IFT.
: C, Four Pole IFT.
: D, Two-Pole, Bipole IFT.
* Output Intensity: Controls variable Output of 00 - 80 V.
* Intensity Balance: Available. Equalize current between Two channels.
* IFT Programs: 21 Pre-programs Condition wise.
* Timer: 01 to 60 minutes. Digital.
* Buzzer: Audio buzzer at the end of Treatment Time.
* Power Consumption: 20watts.
* Power Supply: 230V AC, 50 Hz.
* Size: L 11.5" x W 8" x H 4.5".
* Weight: 2.5 kg. (Approx.).
* Accessories:
* Four, big size Electrodes.
* Four, small size Electrodes.
* Four, Electrode wires.
* Gel, One bottle,
* Velcro Straps to hold/tie Pads - 2,
* User manual.
Interferential current stimulation is effective upon the Nerves, Muscles, Arteries, and Veins. The current is able to penetrate tissues to a much greater depth, with a soft simulative effect, thus assuring an exclusive range of application.
Product Specifications:
* Russian Current: 2500Hz Carrier frequency.
* Medium Frequency: 2 kHz and 4 kHz.
* IF Out-Put; Channel-1, 4000 - 4250Hz depending on the base & spectrum control.
: Channel-2, 4000Hz (Constant)
* Base AMF: 0 to 100 Hz.
* Sweep AMF: 0 to 150 Hz.
* Form: 3 Position, Rectangular 1/1 Sec., Trapezoidal 1/5 Sec., Triangular 6/6 Sec.
* Therapy Mode:
: A, Four Pole, 45 deg. Vector IFT.
: B, Four Pole, 90 deg. Vector IFT.
: C, Four Pole IFT.
: D, Two-Pole, Bipole IFT.
* Output Intensity: Controls variable Output of 00 - 80 V.
* Intensity Balance: Available. Equalize current between Two channels.
* IFT Programs: 21 Pre-programs Condition wise.
* Timer: 01 to 60 minutes. Digital.
* Buzzer: Audio buzzer at the end of Treatment Time.
* Power Consumption: 20watts.
* Power Supply: 230V AC, 50 Hz.
* Size: L 11.5" x W 8" x H 4.5".
* Weight: 2.5 kg. (Approx.).
* Accessories:
* Four, big size Electrodes.
* Four, small size Electrodes.
* Four, Electrode wires.
* Gel, One bottle,
* Velcro Straps to hold/tie Pads - 2,
* User manual.
Technical Specification | |
Power supply | 230 V AC, 50 Hz |
Russian Current | 2500Hz Carrier freq. |
Medium Frequency | 4 KHz, 2 KHz |
Base | 0 to 100 Hz |
Sweep | 0 to 150 Hz |
Form | Triangular 6/6 Sec |
Trapezoidal 1/5 Sec | |
Rectangular 1/1 Sec | |
Mode | (4pv) 45° Four pole vector Interferential |
(4pv) 90° Four pole Vector Interferential | |
(4p) Four pole Interferential Therapy | |
(2p) Two pole Bipolar Interferential Therapy | |
Output Mode | Pads |
Intensity | Control variable output of 0-60 mA |
Timer | 0-60 Minute |
Buzzer | Audio buzzer at the end of the treatment time |
Weight | 2.5 Kg |
Size ( L x W x H ) | 11.5 Inch x 8 Inch x 4.5 Inch |
Accessories supplied | |
• Electrode Wire | 4 |
• Rubber Pads | 2 sizes |
• Velcro Strap (Pair) | 1 |
• Gel | 1 |
Share your thoughts with everyone